GROUP PDF |
GEN ET-300T SERIES, WITH
IGBT RECTIFIER, OUTPUT ISOLATION TRANSFORMER
10- 400kVA |
UPS |
BATTERY OPTIONS |
TIME |
Model |
Power |
Battery
Qty |
Battery |
Battery
Cabinet |
Battery
Cable Breaker |
Time (Minutes) |
|
GEN ET-310T |
10kVA |
52 |
12V 4,5AH |
BATTERY 10T |
Included |
5 / 15 |
|
52 |
12V 7AH |
BATTERY 10T |
Included |
11 / 40 |
|
52 |
12V 9AH |
BATTERY 10T |
Included |
20 / 46 |
|
52 |
12V 12AH |
BC01MP-1K |
OPT |
26 / 61 |
|
52 |
12V 20AH |
BC01MP-1K |
OPT |
53 / 122 |
|
52 |
12V 24AH |
BC01MP-2K |
OPT |
69 / 174 |
|
Model |
Power |
Battery
Qty |
Battery |
Battery
Cabinet |
Battery
Cable Breaker |
Time (Minutes) |
|
GEN ET-315T |
15kVA |
52 |
12V 7AH |
BATTERY 10T |
Included |
5 / 21 |
|
52 |
12V
9AH |
BATTERY 10T |
Included |
10 / 29 |
|
52 |
12V 12AH |
BC01MP-1K |
OPT |
14 / 35 |
|
52 |
12V 20AH |
BC01MP-1K |
OPT |
30 / 71 |
|
52 |
12V 24AH |
BC01MP-2K |
OPT |
44 / 92 |
|
Model |
Power |
Battery
Qty |
Battery |
Battery
Cabinet |
Battery
Cable Breaker |
Time (Minutes) |
|
GEN ET-320T |
20kVA |
52 |
12V 7AH |
BATTERY 10T |
Included |
4 / 13 |
|
52 |
12V
9AH |
BATTERY 10T |
Included |
8 / 20 |
|
52 |
12V 12AH |
BC01MP-1K |
OPT |
9 / 26 |
|
52 |
12V 20AH |
BC01MP-1K |
OPT |
20 / 53 |
|
52 |
12V 24AH |
BC01MP-2K |
OPT |
31 / 69 |
|
52 |
12V 40AH |
BC01MP-2K |
OPT |
58 / 131 |
|
Model |
Power |
Battery
Qty |
Battery |
Battery
Cabinet |
Battery
Cable Breaker |
Time (Minutes) |
|
GEN ET-330T |
30kVA |
52 |
12V 12AH |
BC01MP-1K |
OPT |
4 / 14 |
|
52 |
12V 20AH |
BC01MP-1K |
OPT |
10 / 30 |
|
52 |
12V 24AH |
BC01MP-2K |
OPT |
19 / 44 |
|
52 |
12V 40AH |
BC01MP-2K |
OPT |
34 / 83 |
|
104 |
12V 24AH |
2 x BC01MP-2K |
OPT |
44 / 106 |
|
52 |
12V 70AH |
2 x BC01MP-2K |
OPT |
66 / 159 |
|
Model |
Power |
Battery
Qty |
Battery |
Battery
Cabinet |
Battery
Cable Breaker |
Time (Minutes) |
|
GEN ET-340T |
40kVA |
52 |
12V 20AH |
BC01MP-1K |
OPT |
6 / 20 |
|
52 |
12V 24AH |
BC01MP-2K |
OPT |
14 / 30 |
|
52 |
12V 40AH |
BC01MP-2K |
OPT |
21 / 58 |
|
104 |
12V 24AH |
2 x BC01MP-2K |
OPT |
31 / 69 |
|
52 |
12V 70AH |
2 x BC01MP-2K |
OPT |
47 / 113 |
|
52 |
12V 80AH |
2 x BC01MP-2K |
OPT |
52 / 118 |
|
Model |
Power |
Battery
Qty |
Battery |
Battery
Cabinet |
Battery
Cable Breaker |
Time (Minutes) |
|
GEN ET-360T |
60kVA |
52 |
12V 24AH |
BC01MP-2K |
OPT |
5 / 19 |
|
52 |
12V 40AH |
BC01MP-2K |
OPT |
7 / 34 |
|
104 |
12V 24AH |
2 x BC01MP-2K |
OPT |
19 / 44 |
|
52 |
12V 70AH |
2 x BC01MP-2K |
OPT |
27 / 66 |
|
52 |
12V 80AH |
2 x BC01MP-2K |
OPT |
31 / 70 |
|
Model |
Power |
Battery
Qty |
Battery |
Battery
Cabinet |
Battery
Cable Breaker |
Time (Minutes) |
|
GEN ET-380T |
80kVA |
52 |
12V 40AH |
BC01MP-2K |
OPT |
5 / 21 |
|
104 |
12V
24AH |
2 x BC01MP-2K |
OPT |
14 / 31 |
|
52 |
12V 70AH |
2 x BC01MP-2K |
OPT |
15 / 47 |
|
52 |
12V 80AH |
2 x BC01MP-2K |
OPT |
26 / 52 |
|
52 |
12V 105AH |
2 x BC01MP-2K |
OPT |
34 / 78 |
|
104 |
12V 70AH |
4 x BC01MP-2K |
OPT |
47 / 141 |
|
Model |
Power |
Battery
Qty |
Battery |
Battery
Cabinet |
Battery
Cable Breaker |
Time (Minutes) |
|
GEN ET-3100T |
100kVA |
104 |
12V 24AH |
2 x BC01MP-2K |
OPT |
9 / 23 |
|
52 |
12V
70AH |
2 x BC01MP-2K |
OPT |
10 / 35 |
|
52 |
12V 80AH |
2 x BC01MP-2K |
OPT |
17 / 40 |
|
52 |
12V 105AH |
2 x BC01MP-2K |
OPT |
28 / 59 |
|
104 |
12V 70AH |
4 x BC01MP-2K |
OPT |
35 / 85 |
|
104 |
12V 80AH |
4 x BC01MP-2K |
OPT |
40 / 90 |
|
|
|
|
|
|
|
|
|
|
|
* Battery duration are
calculated as %100 and %50 loads. |
|
|
|
* Battery duration are
calculated under 0,7 Pf. |
|
|
|
* Generg will supply
min. 10 years spare parts for the products. |
|
|
|
* Warranty is 2 years
for manufacturer defects. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|